1、Applicable Products
Overhead Showers Hand Showers (Lever Type) Hand Showers (Push Button Type)
2、Equipment Functions:
(1) Heating (hot water ≤70℃) (Machine function)
(2) Cooling (cold water ≥8℃) (Machine function, only equipped for models complying with ASME A112.18.1)
(3) Water supply (Pressure range: static pressure 0.1MPa ~ 0.8MPa; flow rate per station: 3 L/min ~ 20 L/min) (Machine function)
(4) Shower function switching (Fixture function)
3、Applicable Standards:
|
Standard |
Relevant Content |
|
GB/T 23447-2023 (Chinese National Standard) |
① 5.13 Shower Function Switching Life ② 5.15 Swivel Performance of Ball Joint ③ 6.13 Test for Shower Function Switching Life ④ 6.15 Test for Swivel Performance of Ball Joint
|
|
BS EN 251:2009 (European Standard) |
① 12.3 Shower Function Switching Life ② 12.4 Swivel Life of Ball Joint
|
|
QB/T 4008-2010 (Industry Standard) |
① 5.12 Shower Function Switching Life ② 5.14 Swivel Performance of Ball Joint ③ 6.12 Test for Function Switching Life ④ 6.14 Test for Swivel Performance
|
|
ASME A112.18.1 (American Standard) |
① 5.10.5 Shower Function Switching Life Test ② 5.10.8 Endurance Test for Hand Shower Hose Connection ③ 5.10.9 Swivel Life Test for Ball Joint
|
4、Detailed Introduction of Test Fixtures:
A. Automatic shower function switching (rotating / pressing) driven by air cylinder or motor.
5、Basic Parameters of Standard Machine:
|
Equipment Dimension |
L1600mm*W900mm*H2000mm |
|
Adjustable Cold Water Temperature Range |
10℃±2 ~ Ambient Temperature |
|
Adjustable Hot Water Temperature Range |
Ambient Temperature ~ 70℃±1℃ |
|
Adjustable Test Water Pressure Range |
Static Pressure 0.1MPa ~ 0.8MPa |
|
Flow Rate |
3 L/min -20L/min |
|
Number of Stations |
2 |
|
Power |
With ASME A112.18.1 (including refrigeration system): 20KW
|
|
Voltage |
380V |
Copyright © 2026 Jiangmen Kerui Automation Equipment Co., Ltd Copyright 粤ICP备2025509368号 XML Map