1、Applicable Products
Pressure Balancing Valves Diverter Cartridges Ceramic Cartridges Quarter-Turn Cartridges
2、Equipment Functions:
(1) Air tightness test for cartridges;
(2) Automatic switching of different gears (cold water / hot water, open / close status);
(3) Quick model changeover.
3、Applicable Standards:
|
Standard |
Relevant Content |
|
GB 18145-2014 (Chinese National Standard) |
① 7.6.2 Tightness Performance ② 8.6.2 Tightness Performance Test
|
|
BS EN 817:2008 (British Standard) |
① 8.3 Upstream Tightness with Cartridge Closed ② 8.4 Downstream Tightness with Cartridge Open ③ 8.7 Cartridge Tightness Performance (Cold & Hot Water Cross Flow)
|
|
BS EN 200:2008 (British Standard) |
① 8.2 Cartridge Tightness Performance ② 8.3 Upstream & Downstream Tightness Test for Cartridge
|
4、Basic Parameters of Standard Machine:
|
Equipment Dimension |
L1000mm*W740mm*H1900mm |
|
Recommended Air Tightness Test Pressure Range |
0.3Mpa~0.6Mpa |
|
Air Tightness Test Accuracy |
1.5CC/Min |
|
Number of Stations |
6 |
|
Number of Test Chambers |
2 pcs per station |
|
Power |
1KW |
|
Voltage |
220V~ |
|
Average Testing Efficiency |
Quarter-turn Cartridge: 5 s/pc
|