1、Applicable Products
Pressure Balancing Valve Diverter Cartridge Ceramic Cartridge Quarter-Turn Cartridge
2、Equipment Functions:
(1) Air tightness test for cartridges;
(2) Automatic sorting of qualified and defective products without manual intervention from cartridge feeding to discharging.
3、Applicable Standards:
|
Standard |
Relevant Content |
|
GB 18145-2014 (Chinese National Standard) |
① 7.6.2 Tightness Performance ② 8.6.2 Tightness Performance Test
|
|
BS EN 817:2008 (British Standard) |
① 8.3 Upstream Tightness with Cartridge Closed ② 8.4 Downstream Tightness with Cartridge Open ③ 8.7 Cartridge Tightness Performance (Cold & Hot Water Cross Flow)
|
|
BS EN 200:2008 (British Standard) |
① 8.2 Cartridge Tightness Performance ② 8.3 Upstream & Downstream Tightness Test for Cartridge
|
|
QB/T 5524-2020 (Chinese Industry Standard) |
① 6.5.1.3 Tightness Performance of Other Mechanical Cartridges |
4、Basic Parameters of Standard Machine:
|
Equipment Dimension |
L1450mm*W2608mm*H1790mm |
|
Recommended Air Tightness Test Pressure Range |
0.3Mpa~0.6Mpa |
|
Air Tightness Test Accuracy |
1.5CC/Min |
|
Number of Stations |
16 |
|
Number of Test Chambers |
2 pcs per station |
|
Power |
2KW |
|
Voltage |
220V~ |
|
Average Testing Efficiency |
3.5 s/pc |
Copyright © 2026 Jiangmen Kerui Automation Equipment Co., Ltd Copyright 粤ICP备2025509368号 XML Map