1、Applicable Products: Faucets
Faucets
2、Equipment Functions:
(1) Faucet high water pressure test
3、Applicable Standards:
|
Standard |
Relevant Content |
|
GB 18145-2014 (Chinese National Standard) |
① 7.6.1 Body Strength: Maintain pressure at 2.5MPa±0.05MPa for 60s±5s, no rupture or permanent deformation. ② 7.6.2 Sealing Pressure Resistance: 2.5MPa upstream of cartridge and 0.4MPa downstream for 60s, no leakage on sealing parts.
|
|
ASME A112.18.1/CSA B125.1 (American Standard) |
① 5.10.3 Burst Pressure: Maintain pressure at 3.45MPa (500PSI) for 1 min with cartridge closed, no rupture. ② 5.10.4 High Pressure Sealing: Maintain pressure at 0.86MPa for 5 min, no leakage at connections.
|
|
BS EN 817:2008 (European Standard) |
① 9.2 Combined Pressure & Sealing Test: Maintain pressure at 1.6MPa for 1 min, no leakage on cartridge and connections. ② 9.3 Body Strength: Maintain pressure at 2.5MPa for 60s, no structural damage.
|
|
GB/T 35763-2017 (Chinese National Standard) |
① 21 Pressure Resistance: Maintain pressure at 2.5MPa for 60s, no deformation or leakage on body. ② 21.2 Burst Pressure: Maintain pressure at 3.0MPa for 1 min, no rupture.
|
|
QB/T 5524-2020 (Chinese Industry Standard) |
① 6.5.2 Hydraulic Mechanical Resistance: Maintain pressure at 3.5MPa for 60s with cartridge closed, no permanent deformation or leakage. |
|
EN 200:2008 (European Standard) |
① 9.4 Cartridge Pressure Sealing Test: Maintain pressure at 1.6MPa for 1 min, no leakage. ② 9.5 Body Strength Test: Maintain pressure at 2.5MPa for 60s, no rupture.
|
4、Basic Parameters of Standard Machine:
|
Equipment Dimension |
L1400mm*W1000mm*H1800mm |
|
Compressed Air Supply Pressure |
≥0.6Mpa |
|
Adjustable Test Water Pressure |
0~3Mpa |
|
Number of Stations |
1 |
|
Power |
4KW |
|
Voltage |
220V |
Copyright © 2026 Jiangmen Kerui Automation Equipment Co., Ltd Copyright 粤ICP备2025509368号 XML Map